Automet® FAB - Integrity Checking

From ML Tech Wiki
Jump to navigation Jump to search

The table below is the integrity report shown during data capture which can be reviewed later as the QA report. The integrity report errors show the difference between the data points captured and the data in the design file in your chosen unit of measurement. These values show true differences for pipe OD/ID, flange OD and PCD, hub OD and support base-plate thickness.

The QA table in the image provides the following info:

Name Numbered spool elements as identified in the design file
Description Description of the spool element
Device The declared device used for this measurement
Coverage <90º = Rejected, 90º~135º = Poor, 135º~180º = OK, 180º~270º = Good, >270º = Very Good
Thickness A check on the support shoe base plate against the design input
Plane Maximum out of plane for all points
Pitch Error between bolt-holes
Diameter Avg Diameter error from design
Diameter Max Diameter error from best-fit circle
PCD Avg PCD error from design
PCD Max PCD error from best-fit circle