Automet® FAB - Vector Error Graphical Report - Analysis Tools
Jump to navigation
Jump to search
Vector error graphical analysis is used to access and manipulate survey data; it also displays survey information such as flange thicknesses and the types of devices used.
- The fit check box allows you to include spool elements in the fit. Unchecking this box removes that item from the mathematical best-fit analysis, but does not remove the values from the report.
- The zero check box forces the flange to zero the error at this element. The default is no flange zeroed and all flanges show the best fit.
- Show for circle fits reveals or hides the circle fit values on the report.
-
Flange 01
-
Flange 02
-
Flange 03
| Flange 01 | Flange 02 | Flange 03 |
|---|---|---|
| Surveyed using type 1 device. | Surveyed using type 7 device. On the back face of flange (indicated by the D). | Surveyed using type 7 device. On the front face of flange. |
| Length is being considered. Fit preference is position. | Length is being considered. Fit preference is position. | Length is being considered. Fit preference is position. |
| No offset when using type 1. | Offset when on back is the full flange thickness including the raised face beacuse D points taken on the back of the flange. | Offset when on front is the raised face only. |
| The initial value for thickness is our database value which can be changed at any time but is retained for future reference. | The initial value for thickness is our database value which can be changed at any time. |